fbpx
UltraTemp VXi Inverter Heat Pump
FIND A DEALER

Pentair UltraTemp® VXi heat pumps are equipped to automatically adjust performance to provide the optimal balance of heating power and efficiency. Just select your desired pool temperature on the LCD display and the UltraTemp’s® onboard AI will do the rest.

 

FEATURED HIGHLIGHTS

  • Full inverter heat pump with variable speed compressor and fan motor. Top Fan design
  • The UltraTemp VXi heat pump offers best in class efficiency with COP ratings far in excess of standard heat pumps
  • Pentair heat pumps use the EPA-recognized, environmentally safe, non-ozone depleting R32 refrigerant.
  • 100% titanium heat exchanger assures corrosion-free performance for extra-long life and value
  • Full-color, LCD touchscreen displays an intuitive menu with easy-to-follow icons and messages
  • Automatic defrost feature senses refrigerant temperature and helps prevent the UltraTemp® heat pump from freezing,
  • Easy barrel union plumbing connections
  • Wi-Fi module included, compatible with app freely available on app store
SPECIFICATIONS
Pentair Top Fan Inverter Heat Pumps
UTHP-13-VXi UTHP-17-VXi UTHP-20-VXi UTHP-20T-VXi UTHP-24-VXi UTHP-24T-VXi
FUNCTION Heating                               Cooling
OPERATING AIR TEMPERATURE [°C] -15°C ~43°C

PERFORMANCE CONDITION (AIR 27°C/WATER 26°C/HUMID. 80%)

HEATING CAPACITY [kW] 3.5~13.5 3.8~17.5 5.2~20.6 5.2~20.6 6.2~24.0 6.2~24.0
HEATING CAPACITY [BTU] 1,190~40,800 12,920~59,500 17,680~70,040 17,680~70,040 21,080~81,600 21,080~81,600
CONSUMED POWER [Kw] 0.26~2.08 0.27~2.73 0.38~3.17 0.38~3.17 0.44~3.53 0.43~3.53
COP 13.5~6.5 13.8~6.4 13.6~6.5 13.6~6.5 14.2~6.8 14.5~6.8

PERFORMANCE CONDITION (AIR 15°C/WATER 26°C/HUMID. 70%)

HEATING CAPACITY [kW] 2.4~10.0 2.8~12.8 4.1~14.8 4.1~14.8 4.8~17.5 4.8~17.5
HEATING CAPACITY [BTU] 8,160~34,000 9,520~43,520 13,940~50,320 13,940~50,320 16,320~59,500 16,320~59,500
CONSUMED POWER [Kw] 0.32~2.13 0.37~2.78 0.55~3.29 0.55~3.29 0.64~3.65 0.64~3.65
COP 7.5~4.7 7.5~4.6 7.5~4.5 7.5~4.5 7.5~4.8 7.5~4.8
PERFORMANCE CONDITION (AIR 35°C/WATER 28°C/HUMID. 35%)
COOLING CAPACITY [kW] 6.2 6.9 12.2 12.2 13.5 13.5
COOLING CAPACITY [Btu] 21154 23543 41626 41626 46062 46062
CONSUMED POWER [kw] 1.78 2.10 3.20 3.20 3.50 3.50
EER 3.48 3.29 3.81 3.81 3.86 3.86

TECHNICAL SPECIFICATIONS

POWER SUPPLY 230V/1Ph/50Hz & 60Hz 230V/1Ph/50Hz & 60Hz 230V/1Ph/50Hz & 60Hz 380V/3Ph/50Hz & 60Hz 230V/1Ph/50Hz & 60Hz 380V/3Ph/50Hz & 60Hz
CASING TYPE ABS
COMPRESSOR  Panasonic Rotary/Inverter
WATER CONNECTION [mm] 50
FAN QUANTITY 1
FAN SPEED [RPM] 500 - 700 600 - 800
COMPRESSOR QUANTITY 1
SOUND PRESSURE 1m [dBA] 41~53 43~54 44~55 44~55 45~56 45~56
WATER FLOW [m3/h] 6.5 8 9.5 9.5 10.0 10.0
WATER PRESSURE DROP (MAX) [kPa] 6.8 8.5 16.2 16.2 16.2 16.2
         
Pentair Top Fan Inverter Heat Pumps
UTHP-28-VXi UTHP-28T-VXi UTHP-32T-VXi
FUNCTION Heating                               Cooling
OPERATING AIR TEMPERATURE [°C] -15°C ~43°C

PERFORMANCE CONDITION (AIR 27°C/WATER 26°C/HUMID. 80%)

HEATING CAPACITY [kW] 8.5~28.0 8.5~28.0 10.4~32.0
HEATING CAPACITY [BTU] 28,900~95,200 28,900~95,200 35,360~108,800
CONSUMED POWER [Kw] 0.60~4.31 0.60~4.31 0.77~4.92
COP 14.2~6.5 14.2~6.5 13.5~6.5

PERFORMANCE CONDITION (AIR 15°C/WATER 26°C/HUMID. 70%)

HEATING CAPACITY [kW] 5.6~20.3 5.6~20.3 6.5~22.5
HEATING CAPACITY [BTU] 19,040~69,020 19,040~69,020 22,100~76,500
CONSUMED POWER [Kw] 0.71~4.14 0.71~4.14 0.88~5.00
COP 7.9~4.9 7.9~4.9 7.4~4.5
PERFORMANCE CONDITION (AIR 35°C/WATER 28°C/HUMID. 35%)
COOLING CAPACITY [kW] 14.5 14.5 14.8
COOLING CAPACITY [Btu] 49474 49474 50498
CONSUMED POWER [kw] 4.50 4.50 4.80
EER 3.22 3.22 3.08

TECHNICAL SPECIFICATIONS

POWER SUPPLY 230V/1Ph/50Hz & 60Hz 380V/3Ph/50Hz & 60Hz 380V/3Ph/50Hz & 60Hz
CASING TYPE ABS
COMPRESSOR  Panasonic Rotary/Inverter
WATER CONNECTION [mm] 50
FAN QUANTITY 1
FAN SPEED [RPM] 600 - 800
COMPRESSOR QUANTITY 1
SOUND PRESSURE 1m [dBA] 47~58 47~58 48~60
WATER FLOW [m3/h] 12.0 12.0 15.0
WATER PRESSURE DROP (MAX) [kPa] 23.8 23.8 23.8
FIND A DISTRIBUTOR/DEALER
SEARCH